Access Control Doorway Antenna

Access Control Doorway Antenna

Model: APRIA90012LX

Frequency Range: 902-928MHz

Polarization: Linear

Gain: 12dBi

Product Descriptions

The APRIA90012LX is a high-gain 902–928 MHz UHF RFID antenna delivering 12 dBi gain with linear polarization. Its 1200 × 100 × 28 mm aluminum profile and hang-mount design provide a narrow vertical beamwidth of 10° and a wide horizontal beamwidth of 150°, making it perfect for precise, long-range coverage. IP54 rated, it is designed for RFID logistics tracking, warehouse management, door control systems, and file cabinet management.

Descriptions

  • 902-928MHz
  • 12dBi
  • Linear Polarization
  • 1200*100*28mm

Applications

  • RFID logistics tracking
  • Warehouse management
  • Door control system
  • File cabinet management

Product Specifications

Electrical Specifications

Frequency

902-928MHz

Gain

12dBi

Beam width

Hor:150°  Ver:10°

Polarization

Linear

VSWR

≤1.5

Impedance

50Ω

Maximum power

100W

Lightning protection

DC Ground

Connector

SMA-Female

 

Mechanical Specifications

Dimension

1200*100*28mm

Net weight

1.3kg

Packing size

125*11*3.5cm

Gross weight

1.4kg

Antenna material

Aluminum

Radome color

White

Installation method

Hang mount

Operating temperature

-20-60℃

IP Rating

IP54

 

Applications

Supply Chain Management

RFID Logistics Tracking

RFID Antenna Warehouse Management

Warehouse Management

door control

Door Control System

File cabinet management

Filing Cabinet Management

PRODUCT SUPPORT

FAQ - 902–928MHz UHF RFID Antenna

Choosing the right 902–928MHz RFID antenna involves more than checking its frequency range. Consider the following factors:​

  • Gain: Determines how RF energy is distributed in the antenna’s radiation pattern.​
  • Beamwidth: Helps define the intended horizontal and vertical coverage.​
  • Polarization: Circular polarization can accommodate variations in tag orientation, while linear polarization can work well when tag alignment is predictable.​
  • Installation: Consider the available mounting space, antenna orientation, and surrounding materials.​
  • Compatibility: Check the reader’s frequency range, impedance, connector interface, and supported RF power.​

The best antenna depends on the reading area, tag placement, and operating requirements of the application.​

The 902–928MHz band is shared by different types of wireless devices, so interference may occur when multiple systems operate nearby. In RFID installations, nearby readers and other RF sources may affect reading consistency, particularly in environments with several wireless systems.​

Interference management usually involves suitable reader configuration, frequency planning, transmit power control, and frequency-hopping techniques where supported by the system. Antenna selection also matters: an appropriate radiation pattern and polarization can help control the intended reading area. Proper impedance matching supports efficient power transfer, but it does not eliminate interference from other devices.​

UHF RFID antennas can be installed at designated entry and exit points to identify tagged items, equipment, or goods as they pass through a doorway. When connected to an RFID reader and access control software, the system can record tag information and support movement monitoring or automated access processes. Antenna placement should be planned according to doorway dimensions, tag positions, and the direction of movement to help achieve consistent identification.

RFID antennas installed near warehouse entrances can identify tagged goods during receiving, dispatch, and internal transfers. By connecting the antennas to RFID readers and warehouse management software, businesses can record goods entering or leaving designated areas and improve inventory visibility. The installation layout should account for the size of goods, tag positions, vehicle or trolley movement, and nearby metal structures. System testing helps reduce missed reads and unintended identification.

A narrow vertical beamwidth can help concentrate the antenna’s main radiation pattern within a more defined vertical direction. In doorway applications, this characteristic may be useful when planning an RFID reading zone around a particular passage or detection height. However, beamwidth alone does not determine the actual reading area. Installation height, antenna orientation, tag position, reader power, and the surrounding environment all influence identification performance.

RFID antenna positioning should be based on the dimensions of the passage, the movement of tagged items, and the required identification area. Antennas may be mounted at suitable positions around an access point to support tag identification as items pass through. Their polarization should also be considered, especially when using linear antennas, because tag orientation can affect reading performance. Testing with the actual tags, reader, and gate structure is important before finalizing the layout.

You may also like

Model: APRIA90010LX
Frequency Range: 902-928MHz
Gain: 10dBi
Polarization: Linear
Dimension: 900*100*28mm

Model: APRIA90010LJ
Frequency Range: 902-928MHz
Gain: 10dBi
Polarization: Linear
Dimension: 1600*60*22mmm

Model: APRIA80012LJ
Frequency Range: 865-868MHz
Gain: 12dBi
Polarization: Linear
Dimension: 1200*100*28mm

Please feel free to contact us by info@airpluxtec.com for more detailed info if you’re interested in this Antenna, or please check here for our more Access Control Doorway Antenna products.

Contact

We are always ready to serve you.

Please feel free to contact us
for any antenna inquiry or requirement.

Leave us a message in the form below and
we will get back to you within 24 hours.